把式(7)中左邊進行數(shù)字化,取溫度變化增量△t=1組成數(shù)據(jù)表格,如表2示。以便進行數(shù)字化處理。

表2 數(shù)字化結(jié)果(-10℃~+85℃) t(℃) Rt/Rto t(℃) Rt/Rto t(℃) Rt/Rto

t(℃)Rt/Rtot(℃)Rt/Rtot(℃)Rt/Rto
-105.104221.133540.337
-94.843231.086550.326
-84.596241.042560.315
-74.364251.000570.305
-64.146260.960580.295
-53.94270.922590.285
-43.745280.885600.276
-33.562290.850610.267
-23.388300.817620.259
-13.225310.785630.25
03.07320.755640.242
12.924330.726650.235
22.785340.698660.227
32.655350.672670.22
42.531360.647680.213
52.414370.622690.207
62.303380.599700.201
72.198390.577710.194
82.098400.556720.189
92.004410.536730.183
101.914420.516740.177
111.829430.498750.172
121.748440.480760.167
131.672450.463770.162
141.599460.447780.157
151.53470.431790.153
161.464480.416800.148
171.402490.401810.144
181.343500.388820.14
191.286510.374830.136
201.232520.361840.132
211.181530.349850.128

把上述表格數(shù)據(jù)存入ROM中。

式(7)右邊值由測量計算得到,用Yt來表示在溫度t℃時的值。根據(jù)Yt在上述數(shù)據(jù)表格中查找,使Yt夾在兩點Rt/Rto之間,這兩點為Yn-1、Yn,則得:
Tt=Yn-1+(Yn-Yn-1)△t

單片機在熱敏電阻測溫線性化中應(yīng)用
選擇t的增量制作數(shù)據(jù)表格,要根據(jù)測溫要求和單片機ROM容量來確定(△t≤1)。
實測對比結(jié)果,如表3示。

表3 實測結(jié)果對比(℃) 點溫計0.01℃ 測量結(jié)果 點溫計0.01℃ 測量結(jié)果

點溫計0.01℃測量結(jié)果點溫計0.01℃測量結(jié)果
-9.1-9.150.9150.9
0.90.960.9150.9
10.910.970.9570.9
20.920.980.9280.9
30.930.984.9984.9
40.8940.9

4 軟件框圖

單片機在熱敏電阻測溫線性化中應(yīng)用

圖2 程序框圖

5 結(jié)論

由NE555和單片機16C54構(gòu)成測溫電路,成本極低,精度又高,且能消除其它元器件參數(shù)變化引起測溫誤差,可廣泛應(yīng)用于家用電器、鍋爐控制。